In this edition of Inside the Cataract Studio, Dr. Wendell Scott walks through real-world applications of the “Hi-Lo” phaco technique (high vacuum with low ultrasound energy) in sterile laser-assisted cataract surgery (SLACS). Through video demonstrations and data from over 1,000 eyes, he compares Venturi and peristaltic systems, revealing how setting adjustments can drive efficiency without compromising safety. With insights from studies presented at ASCRS and published in peer-reviewed journals, this segment equips cataract surgeons with practical strategies to enhance chamber stability and streamline nuclear disassembly. Whether refining routine workflows or building confidence with phaco settings, the case-based discussion offers valuable takeaways for any surgical practice.
Introduction to Hi-Lo Phacoemulsification

Dr. Scott:
Greetings to everyone. Today I want to talk about the concept of Hi-Lo phaco, and we will be talking about that in relation to laser cataract surgery, or SLACS, as I prefer to call it, in the way that we use it here at our facility here at Mercy.
Hi-Lo phaco refers to high vacuum in low phacoemulsification energy. SLACS is a term that stands for sterile laser-assisted cataract surgery, and I say sterile because it’s performed in the operating room. Of course a lot of laser-assisted cataract surgery is performed prior to the patient going into the operating room, but this is really, I think, the next generation of robotic surgery.
More and more people are recognizing that indications for SLACS include really difficult types of surgeries, but less time has been spent really talking about routine cataract surgery and how optimizing our laser and phacoemulsification settings can improve outcomes.
So new phaco systems and platforms have really improved and really helped us with maintaining chamber stability. Understanding how to efficiently use the maximum vacuum and to use the lowest phaco power necessary can improve our outcomes and decrease complications.
One of the basic choices in phacoemulsification is Venturi versus peristaltic vacuum. So the vacuum is created in different ways, and these are things that make a difference in how they actually are applied within the eye. Venturi vacuum’s created by gas flow across an opening, and so the pressure is in a rigid cassette. In peristaltic vacuum it’s created by a peristaltic pump.
Software helps prevent the post-occlusion surge with both systems, but your settings matter. Maintaining chamber stability is dependent on in your settings, the inflow, which is really via the sleeve, bottle height, and forced infusion, and outflow fluid through the tip and near incisions. Understanding the vacuum effect is critical for the safety and efficiency.
To better understand how this works with routine cataract surgery, we did a clinical study comparing Venturi and peristaltic-based phacoemulsification at our institution. This was presented at ASCRS and also published in the Canadian Journal of Ophthalmology. So this study involved 995 eyes, so a large study, and these were all patients with just moderate nuclear sclerosis, no other pathology, and equivalent settings for Venturi and peristaltic.
We also did a randomized controlled trial, and this is also presented at ASCRS and published in the Journal of Cataract and Refractive Surgery. In this study, there were 111 patients and a total of 222 eyes, and they were randomized.
So both studies really showed that Venturi was more efficient, if you want to look at it that way, but it’s also interesting to note that the procedure and the efficiencies can be gained with either Venturi or peristaltic using the Hi-Lo phaco settings. Also significant is that the complication rates were very low. Out of the clinical study of the 995 eyes, you can see there were 2 posterior capsule ruptures without vitreous loss, 1 in each group, and there were 3 anterior capsule tears, 2 in the Venturi, 1 in the peristaltic group.
So this is the kind of complication rate we want for routine cataract surgery, and I think it’s important to separate out those complex surgeries that we do from these when we want to try to analyze both the efficiency and the complication rates.
Here the phacoemulsification settings have been used in both of the studies, and you can see that this is maximum vacuum at 600, this is 1% power, the lowest power possible, and the bottle height is actually at a moderate level of 100 cm.
Next will be videos of a Venturi case and a peristaltic case and you can see how they compare. So watching this, you’ll see that the first thing we do is to basically crack the nucleus along the fracture line in half and rotate it, bringing it into position where I can lift it and vacuum at the same time. So if you’ll watch on the lower right-hand part of the screen, you’ll see the vacuum level and the power. So now we’re bringing that piece, the second half, into the same position using maximum vacuum, and you’ll see the power going on and off, but just at 1%. So the idea really is to maximize the vacuum and to use the minimal amount of power necessary. The chop instrument serves as a protection of the posterior capsule by the angulation between the chop and the phaco tip. We use Betadine irrigation throughout the surgery and now the irrigation and aspiration of the cortical material also follow the vacuum, and see this is also in Venturi mode. And you’ll see the truncated edge of the cortex being brought into the vacuum, and using the vacuum just as needed to do that. I also used the Venturi vacuum for the polishing. Of course you can preset the amount of the vacuum, but it’s maintained at a lower level as well.
This case, we’re using peristaltic settings, and this lens is a little bit softer. It’s firm enough to crack into the hemi split but soft enough that the aspiration flow is really enough to engage it, which really helps keep it at the tip to apply the maximum vacuum. And so I think that in a case like this, it is helpful to prevent the post-occlusion surge that you might see, and so it is one of the reasons why some people prefer the peristaltic setting because you see the interplay of the vacuum and the aspiration flow and just going to 0.
This slide compares studies in which we have information on peristaltic settings for conventional and FLACS and then for EPT and Venturi conventional and FLACS. One of the things that I think makes sense for like why peristaltic can be perhaps not as efficient is because the aspiration flow rate attracts the lens material to the tip, but the occlusion is really necessary to reach the preset vacuum levels. The femtosecond-treated lens creates fragments and may not fully occlude the phacoemulsification tip. This prevents the vacuum from further increasing and there’s, as we’ll see in some other videos, this interplay between going between aspiration flow rate and peristaltic.
The other thing that we’ve noted is that a lot of surgeons tend to use the same technique that they have used for non-femto-treated lenses, and they just don’t work as well because they’re really used to depending on that occlusion of the tip. And you see that on the left side of the graph there, where the studies are peristaltic conventional and peristaltic FLACS, and you don’t see that much difference. But if you look at the studies where we do have EPT comparison data for Venturi and conventional, you can see that the Venturi FLACS is lower for all those studies. And when you compare our Hi-Lo phaco settings, which is on the far right of the graph, you can see that those are very low in comparison.
For some of you, this slide will be something you don’t want to really pay that much attention to, but for persons who are really into this and comparing phaco power, I wanted to include it because there’s not another good reference in the literature that kind of pulls this all together. So I won’t just read the slide to you, but I think you just have to realize that different platforms record different things, and to make sense of this, you have to have a way to know what the mathematical relationship of those things are.
The other aspect of comparing platforms, as you see like the EPTs, the energy used when 100% of the ultrasound power is applied for 1 second, okay, but there is not a standardization for what 100% of ultrasound power is, so that is a variable that also has not really been transparently used to compare units. But for those interested, please note this is a way that you can think of what power you’re using, in comparison to others, who are using other platforms.
To end this session, let’s look at one more video using the peristaltic mode. I think that it might be good to look at the settings and how they interplay and think about how this Hi-Lo phaco works.
This Hi-Lo technique of phaco surgery where it’s high vacuum and low power can also be used with the peristaltic mode. The thing to watch as we’re reviewing the peristaltic cases is to watch the aspiration in the vacuum in the lower right-hand corner. So the aspiration is helping you pull that lens into position, and when the tip becomes occluded, you’ll see the vacuum rise and the aspiration fall. That is really intended to try to help you not have any residual vacuum once the piece flows into the phaco tip. So we’ve removed one half, going for the second half. Again, we’re looking for lens purchase, and when you see the aspiration drop and the vacuum rise, that’s when the tip’s occluded, when you have good lens purchase. And so this dance between the two is what you watch for and try to understand with the peristaltic settings.
Thank you for your interest. We have more to get into with really looking at the details and how you personally can become more acquainted with the concept of the Hi-Lo phaco.
Ready to Claim Your Credits?
You have attempts to pass this post-test. Take your time and review carefully before submitting.
Good luck!
Overview
Disclosure of Relevant Financial Relationships
In accordance with the ACCME Standards for Integrity and Independence, it is the policy of Evolve Medical Education, LLC (Evolve) that faculty and other individuals who are in the position to control the content of this activity disclose any real or apparent financial relationships relating to the topics of this educational activity. Evolve Medical Education, LLC (Evolve) has full policies in place that have identified and mitigated financial relationships and conflicts of interest to ensure independence, objectivity, balance, and scientific accuracy prior to this educational activity.
The following faculty/staff members have reported financial relationships with ineligible companies within the last 24 months.
Faculty:
Wendell J. Scott, MD
Mercy Clinic Eye Specialists
Springfield, MO
Consultant: Johnson & Johnson Vision
Reviewers/Content Planners/Authors:- Cindy Davidson has no relevant relationships to disclose.
- Erika Langsfeld, PhD,has no relevant relationships to disclose.
- Mike Taggart, MD, has no relevant relationships to disclose.
Learning Objectives
Upon completion of this activity, learners should be better able to:
Manage machine fluidics to enhance chamber stability and minimize complications during cataract surgery
Target Audience
This activity has been designed to meet the educational needs of ophthalmologists.
Accreditation and Credit Designation Statements
In support of improving patient care, Global Learning Collaborative (GLC) is jointly accredited by the Accreditation Council for Continuing Medical Education (ACCME), the Accreditation Council for Pharmacy Education (ACPE), and the American Nurses Credentialing Center (ANCC) to provide continuing education for the healthcare team.
Global Learning Collaborative (GLC) designates this enduring activity for a maximum of 0.25 AMA PRA Category 1 Credit(s)™. Physicians should claim only the credit commensurate with the extent of their participation in the activity.Provider(s)/Educational Partner(s)

Evolve Medical Education LLC (Evolve) is a leader in cultivating health care for patients by educating clinical competence of the health care team. Evolve achieves this by developing and distributing high-quality, evidence-based, valid, independent CME/CE activities in a variety of learning formats. These activities are designed to increase clinician’s knowledge, skills, competence and professional performance as well as to promote professional growth, maintenance of licensure, and support quality change in care of patients.Commercial Support
This activity is supported by an independent medical education grant from Johnson & Johnson Surgical Vision Inc.
Disclaimer
The views and opinions expressed in this educational activity are those of the faculty and do not necessarily represent the views of Evolve. This presentation is not intended to define an exclusive course of patient management; the participant should use his/her clinical judgment, knowledge, experience, and diagnostic skills in applying or adopting for professional use any of the information provided herein. Any procedures, medications, or other courses of diagnosis or treatment discussed or suggested in this activity should not be used by clinicians without evaluation of their patients’ conditions and contraindications or dangers in use, review of any applicable manufacturer’s product information, and comparison with recommendations of other authorities. Links to other sites may be provided as additional sources of information.
Reproduction Prohibited
Reproduction of this material is not permitted without written permission from the copyright owner.
The views and opinions expressed in this educational activity are those of the faculty and do not necessarily represent the views of Evolve or Johnson & Johnson Surgical Vision Inc.
This activity is designed for educational purposes. Participants have a responsibility to utilize this information to enhance their professional development to improve patient outcomes. Conclusions drawn by the participants should be derived from careful consideration of all available scientific information. The participant should use his/her clinical judgment, knowledge, experience, and diagnostic decision-making before applying any information, whether provided here or by others, for any professional use.System Requirements
- Supported Browsers (2 most recent versions):
- Google Chrome for Windows, Mac OS, iOS, and Android
- Apple Safari for Mac OS and iOS
- Mozilla Firefox for Windows, Mac OS, iOS, and Android
- Microsoft Edge for Windows
- Recommended Internet Speed: 5Mbps+
Publication Dates
Release Date:
Expiration Date:
videoInside the Cataracts Studio: Advanced Fluidics, Ergonomics, and Techniques for Complex Cases - Introducing Robotic SLACS
Show more
Overview
In this edition of Inside the Cataract Studio, Dr. Wendell Scott walks through real-world applications of the “Hi-Lo” phaco technique (high vacuum with low ultrasound energy) in sterile laser-assisted cataract surgery (SLACS). Through video demonstrations and data from over 1,000 eyes, he compares Venturi and peristaltic systems, revealing how setting adjustments can drive efficiency without compromising safety. With insights from studies presented at ASCRS and published in peer-reviewed journals, this segment equips cataract surgeons with practical strategies to enhance chamber stability and streamline nuclear disassembly. Whether refining routine workflows or building confidence with phaco settings, the case-based discussion offers valuable takeaways for any surgical practice.
Disclosure of Relevant Financial Relationships
In accordance with the ACCME Standards for Integrity and Independence, it is the policy of Evolve Medical Education, LLC (Evolve) that faculty and other individuals who are in the position to control the content of this activity disclose any real or apparent financial relationships relating to the topics of this educational activity. Evolve Medical Education, LLC (Evolve) has full policies in place that have identified and mitigated financial relationships and conflicts of interest to ensure independence, objectivity, balance, and scientific accuracy prior to this educational activity.
The following faculty/staff members have reported financial relationships with ineligible companies within the last 24 months.
Faculty:
Wendell J. Scott, MD
Mercy Clinic Eye Specialists
Springfield, MO
Consultant: Johnson & Johnson Vision
Reviewers/Content Planners/Authors:- Cindy Davidson has no relevant relationships to disclose.
- Erika Langsfeld, PhD,has no relevant relationships to disclose.
- Mike Taggart, MD, has no relevant relationships to disclose.
Learning Objectives
Upon completion of this activity, learners should be better able to:
Manage machine fluidics to enhance chamber stability and minimize complications during cataract surgery
Target Audience
This activity has been designed to meet the educational needs of ophthalmologists.
Accreditation and Credit Designation Statements
In support of improving patient care, Global Learning Collaborative (GLC) is jointly accredited by the Accreditation Council for Continuing Medical Education (ACCME), the Accreditation Council for Pharmacy Education (ACPE), and the American Nurses Credentialing Center (ANCC) to provide continuing education for the healthcare team.
Global Learning Collaborative (GLC) designates this enduring activity for a maximum of 0.25 AMA PRA Category 1 Credit(s)™. Physicians should claim only the credit commensurate with the extent of their participation in the activity.Provider(s)/Educational Partner(s)

Evolve Medical Education LLC (Evolve) is a leader in cultivating health care for patients by educating clinical competence of the health care team. Evolve achieves this by developing and distributing high-quality, evidence-based, valid, independent CME/CE activities in a variety of learning formats. These activities are designed to increase clinician’s knowledge, skills, competence and professional performance as well as to promote professional growth, maintenance of licensure, and support quality change in care of patients.Commercial Support
This activity is supported by an independent medical education grant from Johnson & Johnson Surgical Vision Inc.
Disclaimer
The views and opinions expressed in this educational activity are those of the faculty and do not necessarily represent the views of Evolve. This presentation is not intended to define an exclusive course of patient management; the participant should use his/her clinical judgment, knowledge, experience, and diagnostic skills in applying or adopting for professional use any of the information provided herein. Any procedures, medications, or other courses of diagnosis or treatment discussed or suggested in this activity should not be used by clinicians without evaluation of their patients’ conditions and contraindications or dangers in use, review of any applicable manufacturer’s product information, and comparison with recommendations of other authorities. Links to other sites may be provided as additional sources of information.
Reproduction Prohibited
Reproduction of this material is not permitted without written permission from the copyright owner.
The views and opinions expressed in this educational activity are those of the faculty and do not necessarily represent the views of Evolve or Johnson & Johnson Surgical Vision Inc.
This activity is designed for educational purposes. Participants have a responsibility to utilize this information to enhance their professional development to improve patient outcomes. Conclusions drawn by the participants should be derived from careful consideration of all available scientific information. The participant should use his/her clinical judgment, knowledge, experience, and diagnostic decision-making before applying any information, whether provided here or by others, for any professional use.System Requirements
- Supported Browsers (2 most recent versions):
- Google Chrome for Windows, Mac OS, iOS, and Android
- Apple Safari for Mac OS and iOS
- Mozilla Firefox for Windows, Mac OS, iOS, and Android
- Microsoft Edge for Windows
- Recommended Internet Speed: 5Mbps+
Publication Dates
Release Date:
Expiration Date:
videoInside the Cataracts Studio: Advanced Fluidics, Ergonomics, and Techniques for Complex Cases - Introducing Robotic SLACS
Show more
Title
Share on ReachMD
CloseProgram Chapters
Segment Chapters
Playlist:
Recommended
We’re glad to see you’re enjoying ReachMD…
but how about a more personalized experience?

